Fleck Valve 5600 Econominder Specifications


Valve Material Noryl
Inlet/Outlet 3/4" Female
Cycles* 6
---------------------------------------------------------------------------------------------------------------------
Flow Rate (50 psi Inlet): Valve Only
Continuous (15 psi Drop) 20gpm
Peak (25 psi Drop) 26gpm
Cv** 5.2
Maximum Backwash (25 psi Drop) 7 gpm
---------------------------------------------------------------------------------------------------------------------
Regeneration:
Downflow/Upflow Yes
Adjustable Time of regeneration and brine fill only
Time Available 120 minutes
---------------------------------------------------------------------------------------------------------------------
Meter Accuracy Range 0.25 - 15 gpm +/- 5%
Meter Capactiy Range Standard: 125 - 2,125 gal.
Extended: 625 - 10,625 gal.
---------------------------------------------------------------------------------------------------------------------
Dimensions Distributor Pilot 13/16" or 1" (1.050 Pipe O.D.)
Drain Pipe 1/2" NPT Female
Brine Line 3/8"
Mounting Base 2 1/2" - 8 NPSM
Height (from top of tank) 7"
---------------------------------------------------------------------------------------------------------------------
Tank Application - Can regenerate/backwash the following:
Water Softener 6" - 12" Diameter
Iron Filter 6" - 10" Diameter
Sediment Filter 6" - 10" Diameter
Carbon Filter 6" - 10" Diameter
Neutralizing Filter 6" - 10" Diameter
---------------------------------------------------------------------------------------------------------------------
Electrical Rating 24v,110v,220v-50Hz,60Hz
Pressure Hydrostatic: 300 psi
Working: 20 - 125 psi
Temperature 34F - 110F
---------------------------------------------------------------------------------------------------------------------

*Cycles Typical Time
1. Preliminary Rinse (Downflow) 5 minutes
2. Backwash (Upflow) 10 minutes
3. Brine and Slow Rinse 50 minutes
4. Rapid Rinse (Upflow) 10 minutes
5. Settling Rinse (Downflow) 5 minutes
and Brine Tank Refill
6. Service (Downflow)
** Cv - Flow rate of valve alone at 1 psi pressure drop.
---------------------------------------------------------------------------------------------------------------------
Options:
1" Inlet/Outlet
Low Water use piston (uses as little as 29 gal. per regeneration)